Return to site

Linn Ekos Serial Numbers

broken image


The following information was compiled from an official Linn customer services document.

The LP12 has had many upgrades through the years. The major ones were given exotic names, like Nirvana, Valhalla, Lingo, Trampolin reflecting the advances in accurate sound reproduction which they represented. There have also been many unnamed improvements like new feet, new baseboard, new armboard, new suspension springs and grommets and new plinth. The list is long and it means that an LP12 need never be out of date.

At the heart of the Lingo are two very low noise crystal oscillators derived from the Linn Numerik digital studio recording system - one for 33.33 rpm and one for 45 rpm. The switch on the turntable selects the appropriate oscillator, the output of which is fed into a synchronous counter to produce a 50 Hz or 67.5 Hz square wave for 33 rpm.

Linn Ekos Serial Numbers

Cirkus Kit

Ekos
  • Linn Ekos 1 Tonearm Serial number 1860 Made Dec 1988 VGC in full working order Included is the Collar/Counterweight/Grey T-Kable/Fixing Bolts No Box/Packing Supplied with 3 months warranty parts and labour.
  • Serial number of unit reviewed: 722671. Price: $1550. Linn Ekos: Fixed-pivot, medium-mass tonearm with fixed headshell and aluminum armtube. Serial number of unit reviewed: Not noted. Price: $2695. Linn Akiva: Low-output moving-coil phono cartridge with line-contact stylus. Tracking force: 1.6-1.9gm.

The Cirkus upgrade to the LP12 focuses on bearing performance and the connection of the bearing housing to the sub-chassis. The improved bearing and stronger sub-chassis arrangement provides the turntable with greater stability and ensures the bearing sits perfectly true to the chassis of the turntable. This in turn minimises the risk of turntable platter movement with respect to the sub-chassis and arm. Even the slightest movement will introduce audible degradation to the reproduced signal. Find a way to my heart.

Together the changes to the bearing and the sub-chassis make an enormous difference to the overall performance of the turntable. The specific changes are as follows :

  • The thickness of the bearing housing mounting flange has been substantially increased and undercuts eliminated to make it many times more rigid. This also allows the use of larger mounting bolts.
  • Increased distance between top and bottom liners in the bearing housing to make it as stable as possible eliminating even the smallest amount of rocking
  • An increase in the height of the bearing housing from the top of its inner liner to increase oil capacity, ensuring proper lubrication of the top bearing at all times
  • Double thickness sub-chassis to improve rigidity, reducing flexing and improving control of the relationship between key components
Linn Ekos Serial Numbers

Cirkus Kit

  • Linn Ekos 1 Tonearm Serial number 1860 Made Dec 1988 VGC in full working order Included is the Collar/Counterweight/Grey T-Kable/Fixing Bolts No Box/Packing Supplied with 3 months warranty parts and labour.
  • Serial number of unit reviewed: 722671. Price: $1550. Linn Ekos: Fixed-pivot, medium-mass tonearm with fixed headshell and aluminum armtube. Serial number of unit reviewed: Not noted. Price: $2695. Linn Akiva: Low-output moving-coil phono cartridge with line-contact stylus. Tracking force: 1.6-1.9gm.

The Cirkus upgrade to the LP12 focuses on bearing performance and the connection of the bearing housing to the sub-chassis. The improved bearing and stronger sub-chassis arrangement provides the turntable with greater stability and ensures the bearing sits perfectly true to the chassis of the turntable. This in turn minimises the risk of turntable platter movement with respect to the sub-chassis and arm. Even the slightest movement will introduce audible degradation to the reproduced signal. Find a way to my heart.

Together the changes to the bearing and the sub-chassis make an enormous difference to the overall performance of the turntable. The specific changes are as follows :

  • The thickness of the bearing housing mounting flange has been substantially increased and undercuts eliminated to make it many times more rigid. This also allows the use of larger mounting bolts.
  • Increased distance between top and bottom liners in the bearing housing to make it as stable as possible eliminating even the smallest amount of rocking
  • An increase in the height of the bearing housing from the top of its inner liner to increase oil capacity, ensuring proper lubrication of the top bearing at all times
  • Double thickness sub-chassis to improve rigidity, reducing flexing and improving control of the relationship between key components

The attached kit of parts, which includes a new inner platter and spindle, is supplied to fit this upgrade. As always with Linn product improvements, new LP12 turntables will incorporate this upgrade as standard.

Linn Ekos Serial Numbers List

All Linn products are subject to continuous development programmes and we aim to make similar advances in sound quality in future as we have in the past.

Lingo Power Supply

Date Introduced: 1990 The Linn Lingo is a high precision, direct coupled, power supply designed to sit alongside the LP12 turntable. The Lingo upgrade moves the LP12's performance into a new league, further distancing it from the competition.

At the heart of the Lingo are two very low noise crystal oscillators derived from the Linn Numerik digital studio recording system - one for 33.33 rpm and one for 45 rpm. The switch on the turntable selects the appropriate oscillator, the output of which is fed into a synchronous counter to produce a 50 Hz or 67.5 Hz square wave for 33 rpm and 45 rpm respectively.

As the LP12 motor runs at its quietest when driven with a clean sinusoidal waveform, a precision filter is employed in the Lingo to remove harmonics from the square wave leaving only a pure wave form.

The most uniform torque is delivered from the motor when both phases are driven at ninety degrees with respect to one another. This is achieved by a ninety degree phase-shift network after the filter. The two resulting sinusoids drive two high voltage class A amplifiers, the outputs of which drive the two motor windings.

The Lingo uses 'stall detection' circuitry to feed the motor with a higher voltage for increased start-up torque. When the platter reaches the selected speed, this load-sensing circuitry reduces the power output. From then on the motor just maintains the platter's own inertia to keep it going silently.

A toroidal transformer on the PCB, and a mains filter, give a very high degree of electrical isolation from the mains voltage supply.

Modification History

yearserialmodification
199390582Cirkus LP12, Cirkus bearing and subchassis upgrade fitted as standard.
199288950Top Plate with additional stud which improves the coupling of the top plate to the Plinth and secures the motor corner.
199187672LP12 mechanics only, LP12 sold as a mechanical assembly only. Three power supply options available: Lingo, Valhalla and Basik. Valhalla and Basik (Basik PSU supplied with 45 rpm adaptor).
199187672Trampolin kit, suspended base board available as an upgrade, solid base board replacing hardboard base
199187206valhalla has motor thrust pad small cap factory fitted (glued in position) to reduce noise level.
199187047lingo has motor thrust pad small cap factory fitted (glued in position) to reduce noise level.
1990N/ALingo direct coupled power supply for the LP12, offers low noise oscillators, precision filtering, separate drive for both phases and electrical isolation from mains supply.
198981000Grommets composition changed to a new harder, denser rubber. Improves performance of suspension.
198979700Motor thrust pad, motor thrust pad replaced with stainless steel ball bearing. Reduces motor noise.
198779160Armboard material changed to MDF core, laminated top and underside. Increases rigidity of armboard, creating improved platform for tonearm.
198770000Bearing housing, improved bearing liner material and thrust pad specification. Bearing liner machined to tighter tolerances, thus creating better speed stability. Changed to black oil. Tightened grinding tolerance.
1986n/aLid is changed for translucent type.
198454100Sub-chassis, added strengthening bar, spot welded in place. Increases rigidity and strength. late '70s Attached strengthening bar with epoxy glue. Superior bond; increases rigidity.
198453000Plinth, enlarged corner blocks, strengthens and increases rigidity of plinth.
198238800Valhalla power supply, electronic speed control with a sophisticated crystal controlled power supply. Isolates the rotation of the turntable motor from variations in the electrical supply.
198132800Nirvana kit Improved material specification of many integral mechanical components. Improved suspension and stability.
197927000Lid and hinges lid prop removed and hinges changed to spring loaded, self supporting.
197823000Top-plate added two holes for 6 x 0.5 self tappers into wood block
19742000Main bearing liner material changed.
19742000Sub-chassis strengthened by addition of strap, spot welded in place.
19742000Motor control motor control pcb changed from terminal strip to small circuit board.
19742000Mains switch changed from two buttons to single switch with mains neon.
19730000Linn LP12 Sondek introduced
-
510(k)|DeNovo|Registration & Listing|Adverse Events|Recalls|PMA|HDE|Classification|Standards
CFR Title 21|Radiation-Emitting Products|X-Ray Assembler|Medsun Reports|CLIA|TPLC

Serial Numbers Microsoft

EKOS CORP. EKOSONIC ENDOVASCULAR SYSTEMBack to Search Results
Model Number 106CM / 12 CM
Device Problems Restricted Flow rate (1248); Improper Flow or Infusion (2954)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/27/2015
Event Type Malfunction
Event Description

Event desc: the ekos catheter would not flush properly. The procedure was able to be completed successfully with another ekos catheter. There were no complications. What was the original intended procedure: pulmonary angiogram with hemodynamic pressures. Install one channel on kodi. Placement of bilateral 12 cm working length ekos sonothrombolysis catheters. Device usage problem: device failed (e. G. Broke, couldn't get it to work or stopped working). Event reported to ekos: the catheter would not flush properly. The catheter was never placed in a patient.

Manufacturer Narrative

Although the user facility report indicated the device was a 12 cm ekosonic device, serial number (b)(4), the device returned to ekos for investigation was a 6 cm ekosonic device, serial number (b)(4). Additionally, although the customer reported the device was never used in a patient, inspection of the returned device confirmed the drug infusion lumens were filled with dried blood. This condition is consistent with having been placed in a patient and the blood filled infusion lumens also most likely caused the reported event. No patient injury was reported and the patient was reported to have a 'good' outcome.

Search Alerts/Recalls

Serial Numbers Nero

New Search | Submit an Adverse Event Report

Linn Ekos 2 Serial Number

Manufacturer (Section D)
EKOS CORP.
11911 n creek parkway south
bothell WA 98011
Manufacturer Contact
11911 n creek parkway south
bothell, WA 98011
4254153132
MDR Report Key4861539
MDR Text Key5851076
Report Number3001627457-2015-00004
Device Sequence Number1
Product Code KRA
Combination Product (Y/N)N
Reporter Country CodeUS
PMA/PMN NumberK140151
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source TypeUser facility
Reporter Occupation RISK MANAGER
Type of ReportInitial
Report Date04/23/2015
1 Device Was Involved in the Event
0 PatientS WERE Involved in the Event:
Date FDA Received06/18/2015
Is This An Adverse Event Report? No
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device EXPIRATION Date08/01/2017
Device MODEL Number106CM / 12 CM
Device Catalogue Number500-55112
Device LOT Number140827045-001
Was Device Available For Evaluation? Yes
Date Returned to Manufacturer02/17/2015
Is The Reporter A Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report Sent to FDA04/01/2015
Distributor Facility Aware Date01/27/2015
Device Age5 mo
Event Location Hospital
Date Manufacturer Received05/15/2015
Was Device Evaluated By Manufacturer? Yes
Date Device Manufactured08/27/2014
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial